JCM, Vol. 13, Pages 2558: Assessment of Effectiveness and Safety of Aspiration-Assisted Nephrostomic Access Sheaths in PCNL and Intrarenal Pressures Evaluation: A Systematic Review of the Literature

3 weeks ago 13

JCM, Vol. 13, Pages 2558: Assessment of Effectiveness and Safety of Aspiration-Assisted Nephrostomic Access Sheaths in PCNL and Intrarenal Pressures Evaluation: A Systematic Review of the Literature

Journal of Clinical Medicine doi: 10.3390/jcm13092558

Authors: Marco Nizzardo Giancarlo Albo Francesco Ripa Ester Zino Elisa De Lorenzis Luca Boeri Fabrizio Longo Emanuele Montanari Stefano Paolo Zanetti

Different suction-assisted nephrostomic sheaths have been developed for percutaneous nephrolithotomy (PCNL). Objectives: (1) To examine PCNL techniques performed with different aspiration-assisted sheaths (Clear Petra® sheath, Superperc, SuperminiPCNL, and a miniPCNL patented sheath), with specific regard to effectiveness and safety outcomes in adult and paediatric patients; (2) to extrapolate intrarenal pressure (IRP) data during these procedures. Methods: A systematic literature search was performed in accordance with PRISMA guidelines. Relevant articles up to 8 February 2024 were included. Results: Twenty-five studies were selected, thirteen retrospective and twelve prospective. The use of four different aspirating sheaths for miniPCNL was reported: Clear Petra® sheath, Superperc, SuperminiPCNL, and a miniPCNL patented sheath. Stone free rates (SFRs) across techniques ranged from 71.3% to 100%, and complication rates from 1.5% to 38.9%. Infectious complication rates varied from 0 to 27.8% and bleeding complication rates from 0 to 8.9%. Most complications were low grade ones. The trend among studies comparing aspiration- and non-aspiration-assisted miniPCNL was towards equivalent or better SFRs and lower overall infectious and bleeding complication rates in suction techniques. Operation time was consistently lower in suction procedures, with a mean shortening of the procedural time of 19 min. Seven studies reported IRP values during suction miniPCNL. Two studies reported satisfactory SFRs and adequate safety profiles in paediatric patient cohorts. Conclusions: MiniPCNL with aspirating sheaths appears to be safe and effective in both adult and paediatric patients. A trend towards a reduction of overall infectious and bleeding complications with respect to non-suction procedures is evident, with comparable or better SFRs and consistently shorter operative times. The IRP profile seems to be safe with the aid of aspirating sheaths. However, high quality evidence on this topic is still lacking.

Read Entire Article